[1]杨艳敏,王运克,田锌如,等.底部腋角配置斜向钢筋装配叠合管廊抗震性能试验研究[J].吉林建筑大学学报,2019,(03):7-11.
 YANG Yan-min,WANG Yun-ke,TIAN Xin-ru,et al.Experimental study on seismic performance of assembled composite pipe gallery with inclined reinforcement at bottom axillary angle[J].Journal of Jilin Jianzhu University,2019,(03):7-11.
点击复制

底部腋角配置斜向钢筋装配叠合管廊抗震性能试验研究(/HTML)
分享到:

《吉林建筑大学学报》[ISSN:2095-8919/CN:22-1413/TU]

卷:
期数:
2019年03期
页码:
7-11
栏目:
工程科技
出版日期:
2019-06-25

文章信息/Info

Title:
Experimental study on seismic performance of assembled composite pipe gallery with inclined reinforcement at bottom axillary angle
文章编号:
2095-8919(2019)03-0007-05
作者:
杨艳敏王运克田锌如龚玉宝李佳忆
(吉林建筑大学 土木工程学院,长春 130118)
Author(s):
YANG Yan-minWANG Yun-keTIAN Xin-ruGONG Yu-baoLI Jia-yi
(School of civil engineering,Jilin Jianzhu university,Changchun 130118,China)
关键词:
装配叠合式管廊斜向钢筋抗震性能
Keywords:
assembled laminated pipe gallerydiagonal reinforcementseismic performance
分类号:
TU 377.1
文献标志码:
A
摘要:
为研究底部腋角配置斜向钢筋装配叠合管廊抗震性能,通过一个管廊进行拟静力试验,测试其在模拟地震力作用下的滞回性能、刚度退化、耗能能力及延性性能等指标,得出结构的承载能力、屈服位移和极限位移等.研究结果表明,底部腋角配置斜向钢筋装配叠合管廊具有较好的滞回性能、变形与耗能能力,且水平卸载后的残余变形较小,有利于结构震后修复.
Abstract:
In order to study the seismic performance of the assembled composite pipe gallery with inclined reinforcement at the bottom axillary angle,a quasi-static test was carried out on a pipe gallery to test its hysteretic performance,stiffness degradation,energy dissipation capacity and ductility performance under the action of simulated seismic force,and the bearing capacity,yield displacement and ultimate displacement of the structure were obtained.The results show that the composite pipe gallery with inclined reinforcement at the bottom axillary angle has better hysteretic performance,deformation and energy dissipation capacity,and the residual deformation after horizontal unloading is small,which is beneficial to the post-earthquake repair of the structure.

参考文献/References:

[1] 田子玄.装配叠合式混凝土地下综合管廊受力性能试验研究[D].哈尔滨:哈尔滨工业大学,2016.
[2] 魏奇科,王宇航,王永超,皮正波,廖小辉,王姝琪,张浩.叠合装配式地下综合管廊节点抗震性能试验研究[J].建筑结构学报,2019,40(2):246-254.
[3] 孔令俊.大型钢筋混凝土箱涵结构拟静力试验与数值分析[D].西安:西安建筑科技大学,2014.
[4] 中华人民共和国住房和城乡建设部.混凝土结构设计规范(GB 50010-2010)[S].北京:中国建筑工业出版社,2011.
[5] 中华人民共和国住房和城乡建设部.建筑抗震设计规范(GB 50011-2010)[S].北京:中国建筑工业出版社,2010.
[6] Kramer S L.Geotechnical earthquake engineering[M].London:Prentice Education,1996:38-212.
[7] 马军卫,潘金龙,尹万云,刘守城,蒋苏童.全装配式钢筋混凝土框架-剪力墙结构抗震性能试验研究[J].建筑结构学报,2017,38(6):12-22.
[8] 何军保,朱张峰,董军.装配式混凝土剪力墙抗震性能试验研究[J].南京工业大学学报(自然科学版),2017,39(4):124-130.
[9] 中华人民共和国住房和城乡建设部.地下结构抗震设计标准(GB/T 51336-2018)[S].北京:中国建筑工业出版社,2018.
[10] 周志祥.高等钢筋混凝土结构[M].北京:人民交通出版社,2002.

备注/Memo

备注/Memo:
收稿日期:2019-04-03
基金项目:吉林省教育厅规划项目(JJKH 20190872 KJ).
作者简介:杨艳敏(1969~),女,吉林省长春市人,教授,硕士.E-mail: 282872984@qq.com.
更新日期/Last Update: 2019-06-25